Compaq StorageWorks HSG60 ACS Solution Software V8.6 for Compaq Tru64 UNIX Installation and Configuration Guide

B–4 HSG60 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide
If the Network Information Services (NIS) are being used to provide named port lookup
services, contact the network administrator to add the correct ports.
The following shows how the network port assignments appear in the services file:
“There is no disk in the drive” Message
When you install the Command Console Client, the software checks the shortcuts on the
desktop and in the Start menu. The installation will check the shortcuts of all users for that
computer, even if they are not currently logged on. You may receive an error message if
any of these shortcuts point to empty floppy drives, empty CD-ROM drives, or missing
removable disks. Do one of the following:
Ignore the error message by clicking Ignore.
Replace the removable disks, and place a disk in the floppy drive and a CD-ROM in
the CD-ROM drive. Then, click Retry.
Adding the Storage Subsystem and its
Host to the Navigation Tree
The Navigation Tree allows you to manage storage over the network by using the Storage
Window. If planning to use pager notification, add the storage subsystem to the Navigation
Tree.
spgui 4998/tcp #Command Console
ccdevmgt 4993/tcp #Device Management Client and
Agent
kzpccconnectport 4991/tcp #KZPCC Client and Agent
kzpccdiscoveryport 4985/tcp #KZPCC Client and Agent
ccfabric 4989/tcp #Fibre Channel Interconnect Agent
spagent 4999/tcp #HS-Series Client and Agent
spagent3 4994/tcp #HSZ22 Client and Agent
ccagent 4997/tcp #RA200 Client and Agent
spagent2 4995/tcp #RA200 Client and Agent