Maximum Link Connection Speed
Network Access Groups (associated with this network)
For each Fibre Channel SAN Fabric:
Fabric name
Fabric port location
Configuration speed
Number of Fibre Channel SAN Fabrics configured in the VC Domain
To add an unconfigured VC Module to a VC Domain Group, the following items must be identical:
Interconnect bays location and model
Enclosure model
Uplinks of the network and Fibre Channel SAN Fabric
Power state of the VC Modules
VC 4.1x features that must be disabled in a VC Domain to be part of a VC Domain
Group with VC firmware 4.0x
The Hide Unused FlexNICs check box is not supported. Do not configure server profiles with
the Hide Unused FlexNICs option checked. (See Figure 12 (page 35)).
Figure 12 Hide unused FlexNICs option
To disable this feature, edit the server profile and uncheck the Hide Unused FlexNICs check
box. If the server profile is assigned to a server that is powered on, ensure that the server is
powered off before editing the server profile.
IPv6 SNMP is not supported. Do not configure any SNMP Access items or trap destination
using IPv6 (see Figure 13 (page 36)).
Requirements for adding a VC Domain to a VC Domain Group 35