Software Owner manual

from FCoE to Ethernet. Also update the server profiles by removing the FCoE connections that
are linked to Flex-10/10D modules.
LACP timers
Do not configure LACP timers in VC Domains, Uplink Sets, or networks with a Long (30 sec)
value. For VC Domain configurations (see Figure 15) there are two possible values:
Short (1 second)
Long (30 second)
For network (see Figure 16) and Uplink Set (see Figure 17) there are three possible values:
Domain-Default which is either Short (1 second) or Long (30 second)
Short (1 second)
Long (30 second)
When the LACP timer configuration is set to long in VC Domains, all Uplink Sets and networks
with a default are automatically using Long (30 sec).
Figure 15 VC Domain LACP timer configuration
Requirements for adding a VC Domain to a VC Domain Group 37