Software Owner manual

Optimized bandwidth types are displayed in the VC Domain properties page and Allocated port
speed (min-max) entry has been added to the Ethernet, Flex -10 iSCSI and FCoE connections
screens. Figure 39 displays an FCoE connections screen example.
Figure 39 FCoE allocated port speed example
You can also view or select a new value for the FCoE connections table preferred port speed on
the edit server profile page. Figure 40 displays an example of preferred port speed (default port
speed when adding a new connection) in the FCoE connections table.
Figure 40 FCoE preferred port speed example
Displaying Converged Uplink sets and FCoE networks
Figure 41 displays Converged Uplink Sets and FCoE networks in the VC Domain details.
Figure 41 VC Domain details for Converged Uplink sets and FCoE networks
Viewing LACP timer attributes for VC Domains
VCM offers you the option of configuring the timeout for LACP which changes the frequency of
control messages (LACPDU). The feature can be either a short duration (1 second) or a long duration
(30 seconds). VCEM displays that information in the VC Domain network details. Figure 42 displays
VC Domain network details with the LACP timer attribute.
VC Domain Maintenance 69