HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

HP_DeviceIndication: Fibre Channel Port status changed to Link Down
Property name Property implementation
AlertType 5 (Device Alert)
EventID 6
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP Fiber Channel
RecommendedActions Check the FC cabling to this port
Reinsert the FC GBIC if it has been unplugged
Replace FC cabling or the FC GBIC if failure continues
SystemName Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary FC HBA port in link down state
EventCategory 11 (I/O Adapter)
ProbableCause 1 (Other)
ProbableCauseDescription FC HBA Port State Changed to Link Down
ProviderVersion
Provider version generating the indication in the format,
<major>.<minor>.<revision>.<build>
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
OSType
On ESXi, 39(VM)
HP Insight Manager WBEM Fibre Channel Host Bus Adapter Provider 49