HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

Property Name
Property Implementation
StatusDescriptions
Descriptive text per OperationalStatus.
StatusDescriptions[0] text per OperationalStatus[0]:
Management Processor Status: Unknown
Management Processor Status: OK
Management Processor Status: Degraded
Management Processor Status: Error
StatusDescriptions[1]
text per OperationalStatus[1]:
Management Processor NIC Status: Unknown
Management Processor NIC Status: OK
Management Processor NIC Status: NIC disconnected
Management Processor NIC Status: NIC failed
Management Processor NIC Status: NIC is disabled
Management Processor NIC Status: Not in use, MP is
utilizing host NIC
HealthState
0
(Unknown), when
OperationalStatus[0]=0
(Unknown)
5 (OK), normal operation
10 (Degraded/Warning), when OperationalStatus[0]=3
(Degraded)
20 (Major failure), when OperationalStatus[0]=6 (Error)
Note:
When a Management Processor is disabled (refer to property
EnabledState) HealthState will always report a state of 5 (OK) so as
not to contribute negatively to overall system status. An MP is disabled
only if the user has manually disabled it via the MP’s RBSU settings; this is
seen as a normal condition.
CIM_LogicalElement
HP Insight Management WBEM Management Processor Lite Provider 6