HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

Property Name
Property Implementation
CIM_SystemSpecificCollection
InstanceID
Unique identifier for this power redundancy instance.
CIM_RedundancySet
MaxNumberSupported
Represents the maximum number of power supplies supported for this
redundancy set.
MinNumberNeeded
Represents the minimum number of power supplies needed to function.
TypeOfSet
3 (Load Balanced)
LoadBalanceAlgorithm
0 (Unknown)
RedundancyStatus
0 (Unknown) if the redundancy status is unknown;
2 (Fully Redundant) if the all power supplies in the set are operating properly
and enough to achieve redundancy;
3 (Degraded Redundancy) if there are at least enough power supplies for the
redundancy set to provide power, but power supplies have failed;
4 (Redundancy Lost) if there are not enough power supplies required to
achieve redundancy, but enough for the redundancy set to provide power;
5 (Overall Failure) if there are not enough power supplies operating properly
for the redundancy set to provide power.
1-2-4 SMX_MemberOfPowerRedundancy Class
The SMX_MemberOfPowerRedundancy class is used to represent an association between
HP_PowerSupply and HP_PowerRedundancySet.
HP Insight Management Power Supply Provider Overview 8