HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

Property Name
Property Implementation
RecommendedActions
Check the power supply configuration and check the
status of the power redundancy. Ensure the system is
being powered adequately. Add or replace power supplies
if necessary.
HP_AlertIndication
Summary
Power redundancy lost
EventCategory
16
(System Power)
ProbableCause
88
(Loss of Redundancy)
ProbableCauseDescription
Power Redundancy has been Lost
1-3-10 HP_DeviceIndication: Power Supply Redundancy Failed
Important: This indication is not supported on HP Proliant systems since redundancy set failure, which is
failure beyond redundancy lost, will cause system shutdown.
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5
(Major)
CIM_AlertIndication
Description
Power redundancy has been lost. RedundancySetCaption
Where: RedundancySetCaption represents the
SMX
_PowerRedundancySet.Caption
for the redundancy set that failed
redundancy.
AlertingManagedElement
WBEM Path of SMX
_PowerRedundancySet
instance representing the
redundancy set where redundancy failed.
AlertingElementFormat
2 (CIMObjectPath)
HP Insight Management Power Supply Provider Overview 33