HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

Table 16-22 Class: SMX_SASStorageCapabilities (CIM_StorageCapabilities)
Property name
Property implementation
ElementType
5 (Storage Pool)
NoSinglePointOfFailure
TrueWhen number of drives > 1 (For example,
Pool can be configured for redundancy.)
FalseWhen number of drives = 1 or Pool is
NonRAID
NoSinglePointOfFailureDefault
TrueWhen number of drives > 1 (For example,
Pool can be configured for redundancy.)
FalseWhen number of drives = 1 or Pool is
NonRAID
PackageRedundancyDefault
0 (When Pool is NonRAID)
1 (When number of drives = 1)
2 (When number of drives > 1)
PackageRedundancyMax
0 (When Pool is NonRAID)
1 (When number of drives = 1)
2 (When number of drives > 1)
PackageRedundancyMin
0
SMX_SASStorageCapabilities
1-1-23 SMX_SASProduct
SMX_SASProduct represents the marketing information for the HBA.
Table 16-23
Class: SMX_SASProduct (CIM_Product)
Property name
Property implementation
CIM_ManagedElement
ElementName Controller name and location
For example, HP 8 INT Port SAS/SATA HBA in Slot 3,
for internal
CIM_Product
IdentifyingNumber
Opaque key
Name
String representing the Marketing Name
Vendor
HP
Version
Firmware version of HBA
SMX_SASProduct
1-1-24 SMX_SASDriveCage