HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

1-2-5 Physical Drive status REBUILDING
Table 16-76 HP_DeviceIndication: Physical Drive status REBUILDING
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity Severity
For example, 2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Rebuilding.
Data is now being rebuilt onto this drive from the RAID
set.
AlertingManagedElement
WBEM Path of disk drive
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
203
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
No action is recommended.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive rebuilding
EventCategory
6 (Primary Storage)
ProbableCause
1 (Other)
ProbableCauseDescription
Physical Drive Rebuilding
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
On ESXi, 39 (VM)
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>