HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

Table 16-87 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name
Property implementation
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Temperature sensor status Warning Condition
EventCategory
24 (Primary Storage Cooling)
ProbableCause
51 (Temperature Unacceptable)
ProbableCauseDescription
Temperature Status Changed to Warning Condition
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
On ESXi, 39(VM)
OSVersion The operating system version of the computer system
generating the indication in the format:
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames
FailureDescription
VariableTypes
1 (String)
VariableValues Short Description of failure
In some cases, the property VariableValues can have
N/A or “” values.