HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

Property Name
Property Implementation
SystemName
SMX_SAArraySystem.Name
CIM_ProtocolController
MaxUnitsControlled
32
CIM_ SCSIProtocolController
HPSA_ SCSIProtocolController
1-2-29 SMX_SAStorageRedundancySet Class
The SMX_SAStorageRedundancySet class implements the HPSA_StorageRedundancySet class and
represents disk sparing aspect of a RAID configuration. There is an instance for every logical drive that has
spare drives configured.
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
ElementName
Storage Redundancy Set
CIM_Collection
CIM_SystemSpecificCollection
InstanceID
Opaque key
CIM_RedundancySet
LoadBalanceAlgorithm
2 (No Load Balancing)
MaxNumberSupported
0
MinNumberNeeded
0
HP Insight Management WBEM Smart Array Provider 52