HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

Property Name
Property Implementation
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Physical Drive is Currently Offline but
operational, Secure Erase is in Progress.
Once the Secure Erase is Complete, please
reinsert the same disk or new disk for the
disk to be operational.
AlertingManagedElement
WBEM Path of SMX_SADiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
2132
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP Smart Array (
RecommendedActions
Replace drive immediately to avoid loss of data.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary
Physical drive status Secure Erase.
EventCategory
6
(Primary Storage)
HP Insight Management WBEM Smart Array Provider 128