HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

Property Name
Property Implementation
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Smart Array controller Cache status has changed to
Permanently Disabled. The controller has detected a
problem with the cache and has disabled the cache
permanently.
AlertingManagedElement
WBEM Path to SMX_SAArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
11
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
Check the cache controller error code and run
diagnostics.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the indication
HP_AlertIndication
Summary
Array controller cache status permanently disabled
EventCategory
6 (Primary Storage)
ProbableCause
35 (Performance Degraded)
ProbableCauseDescription
Array Controller Cache Status Changed to Permanently
HP Insight Management WBEM Smart Array Provider 206