HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

Property Name
Property Implementation
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Smart Array Controller encryption CSP NVRAM status has changed to
Failed because of CSP NVRAM dtection failure
AlertingManagedElement
WBEM Path to
SMX_SAArrayController
class.
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
16
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
Check the controller encryption error code and run diagnostics.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName
of the computer system generating the indication
HP_AlertIndication
Summary
Array controller encryption CSP NVRAM status failed
EventCategory
6 (Primary Storage)
ProbableCause
24 (I/O device error)
ProbableCauseDescription
Array Controller encryption CSP NVRAM status has changed to
failed.
NetworkAddresses
Contains a list of all the IP addresses of the computer system generating
the indication
HP Insight Management WBEM Smart Array Provider 223