HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

Property Name
Property Implementation
HP_DeviceIndication
DeviceModel
Array Controller Model string
1-3-40 HP_DeviceIndication: Enclosure Power Supply Status
changed to Non Redundant
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3
(Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Power Subsystem status has changed
to non-redundant.
AlertingManagedElement
WBEM Path of
SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
301
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
HP Insight Management WBEM Smart Array Provider 226