HP Insight Management WBEM Providers for HP integrated VMware vSphere 5.1 U2 February 2014 Datasheets

Property Name
Property Implementation
CIM_PhysicalPackage
ConnectorLayout
6 (Slot)
Number
<n>
Where: <n> represents the number of the fan slot.
1-2-15 SMX_SystemFanSlot Class
The SMX_SystemFanSlot class implements the HP_FanSlot class and association the
HP_ComputerSystemChassis instance with HP_FanSlot.
The following table lists the properties implemented.
Property Name
Property Implementation
GroupComponent
References
HP_ComputerSystemChassis
PartComponent
References
HP_FanSlot
1-2-16 SMX_FanInSlot Class
The SMX_FanInSlot class implements the HP_FanInSlot class and associates the HP_FanSlot instance
with
HP_FanModule instances.
The following table lists the properties implemented.
Property Name
Property Implementation
Antecedent
References HP_FanSlot
Dependent
References HP_FanModule
1-2-17 SMX_FanSpeedSensor
SMX_FanSpeedSensor implements CIM_NumericSensor and is used to model fan tachometer sensors
on Servers.
Property Name
Property Implementation