HP Insight Management WBEM Providers for vSphere 5.5 and 5.5 U1 June 2014 SNMP Data Migration
Trap OID
1.3.6.1.4.1.232.6
Trap OID Name
cpqDaAccelBadDataTrap
Indication Class
SMX_SmartArrayIndication
Indication ProviderName
“HP Smart Array”
Indication EventID
“9”, “10”, “11”, “12”
Notes
This trap will not be generated for this condition.
cpqDa6AccelStatusChange will be generated.
Trap OID
1.3.6.1.4.1.232.7
Trap OID Name
cpqDaAccelBatteryFailed
Indication Class
SMX_SmartArrayIndication
Indication ProviderName
“HP Smart Array”
Indication EventID
“6”, “7”, “8”
Notes
This trap will not be generated for this condition.
cpqDa6BatteryFailed will be generated.
Trap OID
1.3.6.1.4.1.232.3001
Trap OID Name
cpqDa2LogDrvStatusChange
Indication Class
SMX_SmartArrayStorageVolumeIndication
Indication ProviderName
“HP Smart Array”
Indication EventID
“101”, “102”, “103” ”,“104”, “105”, “106”,
“107”,”108”,”109”,”110”,”111”,”112”,”113”
Notes
This trap will not be generated for this condition.
cpqDa6LogDrvStatusChange will be generated.
Trap OID
1.3.6.1.4.1.232.3002
Trap OID Name
cpqDa2SpareStatusChange
Indication Class
Not Implemented
Indication ProviderName
Indication EventID
Notes
Trap OID
1.3.6.1.4.1.232.3003
Trap OID Name
cpqDa2PhyDrvStatusChange
Indication Class
SMX_SmartArrayDiskDriveIndication