HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

1-3-5 HP_DeviceIndication: ASR Reboot Occurred
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description The system has rebooted from an Automatic Server
Recovery (ASR) event.
AlertType
5 (Device Alert)
EventID
1
ProviderName HP Recovery
RecommendedActions
Determine the nature of the ASR event and take
corrective action.
HP_AlertIndication
Summary
ASR reboot occurred
EventCategory
16 (System Power)
ProbableCause
111 (Timeout)
ProbableCauseDescription
ASR reboot occurred
1-3-6 HP_DeviceIndication: Thermal Reboot Occurred
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
HP Insight Manager WBEM Base Server Provider Overview 30