HP Insight Management WBEM Providers SNMP Data Migration for vSphere 5.1 U2 September 2013
Table Of Contents
- 1 Introduction
- 2 Overview of the Insight Management MIB
- 3 High Level Mapping
- 4 Server MIB Variable to WBEM Property Mappings
- 5 Storage MIB Variable to WBEM Property Mappings
- 6 Network MIB Variable to WBEM Property Mappings
- 7 Server Trap to Indication Mappings
- 8 Storage Trap to Indication Mappings
- 9 Network Trap to Indication Mappings
- 10 Revisions
Trap OID
1.3.6.1.4.1.232.6029
Trap OID Name
cpqHe3CorrMemReplaceMemModule
Indication Class
SMX_MemoryIndication
Indication ProviderName
“HP Memory”
Indication EventID
“1”
Notes
This trap will be generated for this condition.
Trap OID
1.3.6.1.4.1.232.6030
Trap OID Name
cpqHe3FltTolPowerSupplyDegraded
Indication Class
SMX_PowerSupplyIndication
Indication ProviderName
“HP Power”
Indication EventID
20
Notes
This trap will not be generated for this condition.
cpqHe4FltPwrSupplyDegraded will be generated.
Trap OID
1.3.6.1.4.1.232.6031
Trap OID Name
cpqHe3FltTolPowerSupplyFailed
Indication Class
SMX_PowerSupplyIndication
Indication ProviderName
“HP Power”
Indication EventID
“3”
Notes
This trap will not be generated for this condition.
cpqHe4FltTolPowerSupplyFailed will be generated.
Trap OID
1.3.6.1.4.1.232.6032
Trap OID Name
cpqHe3FltTolPowerRedundancyLost
Indication Class
SMX_PowerSupplyIndication
Indication ProviderName
“HP Power”
Indication EventID
“5” or “6”
Notes
This trap will ge generated for this condition. The two
different indications differentiate between redundancy
reduced and redundancy lost.
Trap OID
1.3.6.1.4.1.232.6033
Trap OID Name
cpqHe3FltTolPowerSupplyInserted