HP Insight Management WBEM Providers for ESXi 5.0 SNMP Migration Guide March 2012

SMX_PowerSupplyIndication
“HP Power”
“3”
This trap will not be generated for this condition.
cpqHe4FltTolPowerSupplyFailed will be generated.
1.3.6.1.4.1.232.6032
cpqHe3FltTolPowerRedundancyLost
SMX_PowerSupplyIndication
“HP Power”
“5” or “6”
This trap will ge generated for this condition. The two
different indications differentiate between redundancy
reduced and redundancy lost.
1.3.6.1.4.1.232.6033
cpqHe3FltTolPowerSupplyInserted
SMX_powerSupplyIndication
“HP Power”
“2”
This trap will be generated for this condition.
1.3.6.1.4.1.232.6034
cpqHe3FltTolPowerSupplyRemoved
SMX_PowerSupplyIndication
“HP Power”
“1”
This trap will be generated for this condition
1.3.6.1.4.1.232.6035
cpqHe3FltTolFanDegraded
SMX_FanIndication
“HP Cooling
“20”