HP Insight Management WBEM Providers for ESXi 5.0 SNMP Migration Guide March 2012
Table Of Contents
- 1 Introduction
- 2 Overview of the Insight Management MIB
- 3 High Level Mapping
- 4 Server MIB Variable to WBEM Property Mappings
- 5 Storage MIB Variable to WBEM Property Mappings
- 6 Network MIB Variable to WBEM Property Mappings
- 7 Server Trap to Indication Mappings
- 8 Storage Trap to Indication Mappings
- 9 Network Trap to Indication Mappings
- 10 Revisions
Trap OID
1.3.6.1.4.1.232.8006
Trap OID Name
cpqSsSidePanelRemoved
Indication Class
Not Implemented
Indication ProviderName
Indication EventID
Notes
Trap OID
1.3.6.1.4.1.232.8007
Trap OID Name
cpqSsPwrSupplyDegraded
Indication Class
SMX_SmartArrayStorageEnclosureIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“303”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs6PwrSupplyStateChange will be generated
Trap OID
1.3.6.1.4.1.232.8008
Trap OID Name
cpqSs3FanStatusChange
Indication Class
SMX_SmartArrayStorageEnclosureIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“304”, “305”, “306”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs6FanStatusChange will be generated
Trap OID
1.3.6.1.4.1.232.8009
Trap OID Name
cpqSs3TempFailed
Indication Class
SMX_SmartArrayStorageEnclosureTempIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“309”
Notes
Only SmartArray supports generating SNMP traps. This
trap will be generated for this condition.