HP Insight Management WBEM Providers for ESXi 5.0 U1 SNMP Migration Guide June 2012
Indication Class
SMX_SmartArrayIndication
Indication ProviderName
“HP Smart Array”
Indication EventID
“9”, “10”, “11”, “12”
Notes
This trap will not be generated for this condition.
cpqDa6AccelStatusChange will be generated.
Trap OID
1.3.6.1.4.1.232.3007
Trap OID Name
cpqDa2AccelBatteryFailed
Indication Class
SMX_SmartArrayIndication
Indication ProviderName
“HP Smart Array”
Indication EventID
“6”, “7”, “8”
Notes
This trap will not be generated for this condition.
cpqDa6AccelBatteryFailed will be generated.
Trap OID
1.3.6.1.4.1.232.3008
Trap OID Name
cpqDa3LogDrvStatusChange
Indication Class
SMX_SmartArrayStorageVolume
Indication ProviderName
“HP Smart Array”
Indication EventID
“101”, “102”, “103”
Notes
This trap will not be generated for this condition.
cpqDa6LogDrvStatusChange will be generated.
Trap OID
1.3.6.1.4.1.232.3009
Trap OID Name
cpqDa3SpareStatusChange
Indication Class
Not Implemented
Indication ProviderName
Indication EventID
Notes
Trap OID
1.3.6.1.4.1.232.3010
Trap OID Name
cpqDa3PhyDrvStatusChange
Indication Class
SMX_SmartArrayDiskDriveIndication
Indication ProviderName
“HP Smart Array”
Indication EventID
“201”, “202”, “203”, “204”
,”205”,”206”,”207”,”208”,”209”,”210”,211”