HP Insight Management WBEM Providers for ESXi 5.0 U1 SNMP Migration Guide June 2012
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“304”, “305”, “306”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs6FanStatusChange will be generated
Trap OID
1.3.6.1.4.1.232.8017
Trap OID Name
cpqSsExPowerSupplyStatusChange
Indication Class
SMX_SmartArrayStorageEnclosureIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“301”, “302”, “303”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs6PwrSupplyStatusChange will be generated
Trap OID
1.3.6.1.4.1.232.8018
Trap OID Name
cpqSsExPowerSupplyUpsStatusChange
Indication Class
SMX_SmartArrayStorageEnclosureIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“301”, “302”, “303”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs6PwrSupplyStatusChange will be generated
Trap OID
1.3.6.1.4.1.232.8019
Trap OID Name
cpqSsExTempSensorStatusChange
Indication Class
SMX_SmartArrayStorageEnclosureTempIndication
SMX_SASIndication
Indication ProviderName
“HP Smart Array”, “HP SAS”
Indication EventID
“307”, “308”, “309”
Notes
Only SmartArray supports generating SNMP traps. This
trap will not be generated for this condition.
cpqSs3TempOK, cpqSs3TempDegraded or