HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

HP Memory Physical Asset Profile
12 HP Confidential Version 1.0
7.1 HP_MemoryCollection (Optional)
There may be one or more instances of HP_MemoryCollection instantiated. Instances of
HP_MemoryModule and HP_MemoryBoard are associated to HP_MemoryCollection through the
HP_MemberOfMemoryCollection association. The HP_MemoryCollection instance is associated to the
HP_ComputerSystem instance through the HP_HostedMemoryCollection association.
7.1.1 HP_MemoryCollection.InstanceID
This property shall be set to the following value: “HPQ:<provider name>:<unique ID>” where <provider
name> is the name of the provider that implements this class and <unique ID> is a unique value for the
instance.
7.2 HP_MemoryRedundancySet (Optional)
There may be one or more instances of HP_MemoryRedundancySet instantiated. Instances of
HP_MemoryBoard are associated to HP_MemoryRedundancySet through the
HP_MemberOfMemoryRedundancySet association. Instances of HP_MemoryRedundancySet are
associated to the HP_ComputerSystem instance through the HP_HostedMemoryRedundancySet
association.
7.2.1 HP_MemoryRedundancySet.InstanceID
This property shall be set to the following value: “HPQ:<provider name>:<unique ID>” where <provider
name> is the name of the provider that implements this class and <unique ID> is a unique value for the
instance.
7.2.2 HP_MemoryRedundancySet.AvailableMemory
This property may be set to a value that specifies the size of memory seen by the Operating System.
Please see MOF for details.
7.2.3 HP_MemoryRedundancySet.TotalMemory
This property may be set to a value that specifies the total size of memory including memory seen by the
Operating System and the memory used for spare, mirrored, or RAID configurations in MB. Please see
MOF for details.
7.2.4 HP_MemoryRedundancySet.OperatingSpeed
This property may be set to a value that specifies the current operating speed of the Advanced Memory
Protection subsystem in MHz. Please see MOF for details.
7.2.5 HP_MemoryRedundancySet.ConfigurationsAvailable
This property may be set values that specify the Advanced Memory Protection Fault Tolerance
configurations available on the system. Please see MOF for details.
7.2.6 HP_MemoryRedundancySet.TargetConfiguration
This property may be set to a value contained in HP_MemoryRedundancySet.ConfigurationsAvailable
that specifies the selected configuration of the Advanced Memory Protection subsystem. Please see
MOF for details.