HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

HP Memory Physical Asset Profile
Version 1.0 HP Confidential 23
Element Name
Requirement Description
Classes
HP_MemoryCollection Optional See sections 7.1 and 10.1
HP_MemoryRedundancySet Optional See sections 7.2 and 10.2
HP_MemberOfMemoryCollection Conditional See sections 7.2.7 and 10.3
HP_MemberOfMemoryRedundancySet Conditional See sections 7.4 and 10.4
HP_HostedMemoryCollection Conditional See sections 7.5 and 10.5
HP_HostedMemoryRedundancySet Conditional See sections 7.6 and 10.6
HP_MemoryModule Mandatory See sections 7.7 and 10.7
HP_MemoryBoard Optional See sections 7.8 and 10.8
HP_RealizesMemoryModule Mandatory See sections 7.8.5 and 10.9
HP_MemoryModuleInSlot Conditional See sections 7.10 and 10.10
HP_MemoryBoardInSlot Conditional See sections 7.11 and 10.11
HP_MemoryModuleOnBoard Conditional See sections 7.12 and 10.12
HP_SystemMemoryModule Mandatory See sections 7.13 and 10.13
HP_SystemMemoryBoard Conditional See sections 7.14 and 10.14
HP_MemoryModuleSlot Optional See sections 7.15 and 10.15
HP_MemoryBoardSlot Optional See sections 7.16 and 10.16
HP_SystemMemoryModuleSlot Optional See sections 7.17 and 10.17
HP_SystemMemoryBoardSlot Optional See sections 7.18 and 10.18
HP_MemoryModuleSlotOnBoard Conditional See sections 7.19 and 10.19
HP_RegisteredProfile Mandatory See section 10.20
Indications
None defined in this profile
10.1 HP_MemoryCollection
HP_ModuleCollection extends the class HP_GroupSystemSpecificCollection in ways that are specific to
HP memory implementations. Implementations shall adhere to the requirements defined in HP WBEM TC
P00113, HP Consolidated Status profile for the class HP_GroupSystemSpecificCollection as well as
additional requirements defined in this section. Implementations shall implement an instance of
HP_MemoryCollection with the values specified.
Table 3 – Class: HP_MemoryCollection
Properties Requirement Notes
InstanceID Mandatory
Key: “HPQ:<provider name>:<unique ID>
where <provider name> is the name of the
provider that implements this class and
<unique ID> is a unique value for the
instance.
10.2 HP_MemoryRedundancySet
HP_ MemoryRedundancySet extends the class CIM_RedundancySet in ways that are specific to HP
memory implementations. Implementations shall adhere to the requirements defined in HP WBEM TC
P00113, HP Consolidated Status profile for the class CIM_RedundancySet as well as additional