HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

HP Memory Physical Asset Profile
Version 1.0 HP Confidential 29
Properties Requirement Notes
Tag Mandatory
Key: “HPQ:<provider name>:<unique ID>
where <provider name> is the name of the
provider that implements this class and
<unique ID> is a unique value for the
instance.
Name Mandatory
“Memory Board n where n represents the
board slot number.
Number Mandatory The board slot number that corresponds
to the memory board slot value printed on
the computer system.
Caption Mandatory
“Memory Board n where n represents the
board slot number.
Description Mandatory
“Memory Board n where n represents the
board slot number. After this string, this
property can optionally contain additional
information about the slot.
ConnectorLayout Mandatory Other(1)
ConnectorDescription Mandatory “Memory Board”
10.17 HP_SystemMemoryModuleSlot
HP_SystemMemoryModuleSlot extends the class CIM_Container in ways that are specific to HP memory
implementation.
Table 19Class: HP_SystemMemoryModuleSlot
Properties Requirement Notes
GroupComponent Mandatory Key: References
HP_ComputerSystemChassis
PartComponent Mandatory Key: References HP_MemoryModuleSlot
10.18 HP_SystemMemoryBoardSlot
HP_SystemMemoryBoardSlot extends the class CIM_Container in ways that are specific to HP memory
implementation.
Table 20Class: HP_SystemMemoryBoardSlot
Properties Requirement Notes
GroupComponent Mandatory Key: References
HP_ComputerSystemChassis
PartComponent Mandatory Key: References HP_MemoryBoardSlot
10.19 HP_MemoryModuleSlotOnBoard
HP_MemoryModuleSlotOnBoard extends the class CIM_Container in ways that are specific to HP
memory implementation.
Table 21Class: HP_MemoryModuleSlotOnBoard