HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

8 Version 1.1.0
CIM_Realizes
see DMTF Physical Asset
profile
HP_RealizesFan
HP_SystemPhysicalFan
CIM_Container
see DMTF Physical Asset
profile
HP_FanInSlot
CIM_PackageInSlot
see DMTF Physical Asset
profile
Figure 2 – HP Fan Physical Asset Profile: Inheritance Hierarchy Diagram
7 Implementation Requirements
This section details the requirements related to the arrangement of instances and properties of instances
for implementations of this profile.
7.1 HP_FanModule
There shall be one instance of HP_FanModule instantiated for each instance of HP_Fan.
7.1.1 HP_FanModule.RemovalConditions
HP_FanModule.RemovalConditions property must be implemented. This property contains enumerations
that describe the fan module’s removal conditions, including its hot swap capability. Please see
DSP1011 Physical Asset Profile.
7.1.2 HP_FanModule.Description
HP_FanModule.Description property may optionally be implemented. This property shall contain a
detailed description of the fan module, including Caption, Name or ElementName, FanType and the
corresponding string value of OperationalStatus[0] or StatusDescriptions[0].
7.2 HP_RealizesFan
There shall be one instance of HP_RealizesFan instantiated for each instance of HP_Fan. This class
associates instances of HP_Fan with a corresponding instance of HP_FanModule.