HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

Version 1.0.2 11
10 CIM Elements
The implementation requirements for the classes and properties described in this section are defined in
the “Implementation Requirements” section (Section 7).
Table 2 – CIM Elements HP Power Supply Profile
Element Name
Requirement
Description
Classes
HP_PowerSupplyModule Mandatory See Sections 7.1 and 10.1
HP_RegisteredProfile Mandatory See Section 10.2
HP_RealizesPowerSupply Mandatory See Sections 7.2 and 10.3
HP_SystemPhysicalPowerSupply Mandatory See Sections 7.3 and 10.4
HP_PowerSupplyInSlot Conditional See Sections 7.4 and 10.5
Indications
None defined in this profile
10.1 HP_PowerSupplyModule
HP_PowerSupplyModule is used to represent a power supply module in a managed system.
Table 3 – Class: HP_PowerSupplyModule
Properties
Requirement
Notes
RemovalConditions Mandatory See Section 7.1.1
10.2 HP_RegisteredProfile
The HP_RegisteredProfile class is defined by the HP Profile Registration Profile.
Table 4 – Class: HP_RegisteredProfile
Properties
Requirement
Description
RegisteredName Mandatory "HP Power Supply Physical Asset"
RegisteredVersion Mandatory “1.0.2”
RegisteredOrganization Mandatory Other (1)
OtherRegisteredOrganization Mandatory “HP WBEM TC”
10.3 HP_RealizesPowerSupply
HP_RealizesPowerSupply is used to represent the association between HP_PowerSupply and
HP_PowerSupplyModule.
Table 5 – Class: HP_RealizesPowerSupply
Properties Requirement Notes
Antecedent Mandatory
Key: References HP_PowerSupplyModule
Dependent Mandatory
Key: References HP_PowerSupply