HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

12 Version 1.0.2
10.4 HP_SystemPhysicalPowerSupply
HP_SystemPhysicalPowerSupply is used to represent the association between CIM_PhysicalPackage
and HP_PowerSupplyModule.
Table 6 – Class: HP_SystemPhysicalPowerSupply
Properties Requirement Notes
GroupComponent Mandatory
Key
: References HP_ComputerSystemChassis
PartComponent Mandatory
Key: References HP_PowerSupplyModule
10.5 HP_PowerSupplyInSlot
HP_PowerSupplyInSlot is used to represent the association between HP_PowerSupplyModule and
CIM_Slot.
Table 7 – Class: HP_PowerSupplyInSlot
Properties Requirement Notes
Antecedent Mandatory
Key: References CIM_Slot
Dependent Mandatory
Key: References HP_PowerSupplyModule
11 Durable Names and Correlatable IDs
Table 8 – Durable Names generated by this Profile
Class Durable Name(s) Source ID
Information
Circumstances for
Change
None Defined
Table 9 – Correlatable IDs generated by this Profile
Class Correlatable ID(s) Source ID
Information
Circumstances for
Change
None Defined