HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

16 Version 1.0.1
1. Use CIM_Realizes association to find HPSA_DiskPhysicalPackage.
2. Use PhysicalElementLocation association to find HPSA_DiskDriveLocation instance
3. Tag/values yields Bay 5
4. Use CIM_Container association to find parent instance of CIM_PhysicalPackage
(HPSA_DriveCage)
5. Use PhysicalElementLocation association to find HPSA_DriveCageLocation instance
6. Tag/values yields Port 1E
7. Use CIM_Container association to find parent instance of CIM_PhysicalPackage
(HPSA_StorageEnclosure)
8. Use PhysicalElementLocation association to find HPSA_StorageEnclsoureLocation instance
9. Tag/values yields Box 1
10. Complete location string would look like “Box 1, Port 1E, Bay 5”
Note attachment to the HBA is via cable and is represented at the Drive Cage level since this could be
duplexed and have more than one drive cage.
The Firmware version for the enclosure can be determined by using association
CIM_ElementSoftwareIdentity from the instance of HPSA_StorageEnclosureProcessor. (This is defined in
DMTF profile DSP1023)