HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

Version 2.0.0 35
Value ValueMap
0
Unknown
1
ACCEL_BATTERY
2
ACCEL_CAPACITOR
3
N/A
HPSA_ArrayController.BatteryStatus
Value indicates the current status of the backup source. The backup source can be a battery or
a capacitor.
Table 8 – HP Smart Array profile: HPSA_ArrayController.BatteryStatus
Value ValueMap
0
Unknown
1
OK
2
Failed
3
Not Fully charged
4
Not Present
HPSA_ArrayController.CacheSizeTotal
Total size of cache memory installed on the controller in bytes.
HPSA_ArrayController.CacheReadPercent
Indicates the amount of cache memory assigned to read operations as a percentage of total
cache memory.
HPSA_ArrayController.CacheWritePercent
Indicates the amount of cache memory assigned to write operations as a percentage of total
cache memory.
HPSA_ArrayController.CacheParityReadErrors
Indicates the number of Cache parity read errors.
HPSA_ArrayController.CacheParityWriteErrors
Indicates the number of Cache parity write errors.
HPSA_ArrayController.CacheSerialNumber
String containing the serial number of the cache board if available.
HPSA_ArrayController.CacheStatus
Overall status of cache memory module. (E.g. Cache may be temporarily disabled while some
rebuild operations are in progress.)
Table 9 – HP Smart Array profile: HPSA_ArrayController.CacheStatus