HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

Version 2.0.0 61
9.7 Disk Sparing Multiple Spares
HPSA_StorageExtent:001
HPSA_StorageExtent:002
HPSA_StorageExtent:003
HPSA_StoragePool:1
Concrete Pool
ConcreteComponent
HPSA_StorageRedundancySet:A
MemberOfCollection
HPSA_StorageExtent:005
Spare
HPSA_StoragePool:1
Concrete Pool
HPSA_StorageExtent:007
HPSA_StorageExtent:008
HPSA_StorageExtent:009
ConcreteComponent
HPSA_StorageRedundancySet:B
MemberOfCollection
IsSpare
HPSA_StorageExtent:004
Spare
IsSpare
Figure 166 - HP Smart Array profile: Disk sparing Multiple Spares
Redundancy sets can have multiple spares and also a disk drive can be a spare to more than one
redundancy set. In Figure 166, we see that HPSA_StorageRedundancySet:A has two CIM_IsSpare
associations to two HPSA_StorageExtent instances. Also, HPSA_StorageExtent:005 has CIM_IsSpare
associations to both HPSA_StorageRedundancySet:A and HPSA_StorageRedundancySet:B.
9.8 Disk Sparing - Drive failure example
The following sections describe the implementation of Disk Sparing for Smart Array controllers.