HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

Version 2.0.0 63
9.8.2 Drive Failed – Data Rebuilding
HPSA_StorageExtent:001
OPStatus = “OK”
HPSA_StorageExtent:002
OPStatus = “OK”
HPSA_StorageExtent:003
OPStatus = “ERROR”
HPSA_StoragePool:1
Concrete Pool
ConcreteComponent
HPSA_StorageRedundancySet:A
MemberOfCollection
HPSA_StorageExtent:004
Spare
OPStatus = “OK,Rebuld”
ExtentStatus = “Rebuild”
IsSpare
HPSA_StorageVolume:100
OpStatus = “Degraded,
Recovering”
PercentComplete = “33”
AllocatedFromStoragePool
Spared
Figure 28 - HP Smart Array profile: Disk sparing Drive failed - rebuilding
Figure 8 shows the instance diagram after one of the data drives has failed. OperationalStatus will show
“ERROR” for the failed drive. The OperationalStatus for the StorageVolume will show
OpStat[0]:“Degraded”, OpStat[1]:”Recovering”. The OperationalStatus for the Spare drive will show
OpStat[0]:“OK” and the ExtentStatus will show OpStat[1]:“Rebuild”. This signifies that data is being rebuilt
to the spare drive. The progress for the rebuild will be shown in HPSA_StorageVolume.PercentComplete.
The CIM_Spared association is used to associate the spare to the failed drive that it has replaced.