HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

64 Version 2.0.0
9.8.3 Drive Failed Rebuild Complete
HPSA_StorageExtent:001
OPStatus = “OK”
HPSA_StorageExtent:002
OPStatus = “OK”
HPSA_StorageExtent:003
OPStatus = “ERROR”
HPSA_StoragePool:1
Concrete Pool
ConcreteComponent
HPSA_StorageRedundancySet:A
MemberOfCollection
HPSA_StorageExtent:004
Spare
OPStatus = “OK”
IsSpare
HPSA_StorageVolume:100
OpStatus = “OK”
AllocatedFromStoragePool
Spared
Figure 29 - HP Smart Array profile: Drive Failed Rebuild complete
Figure 9 shows that the rebuild operation has completed. The OperationalStatus values are now “OK” for
the StorageVolume and the Spare Drive since rebuild is complete and redundancy has been restored.
Note the StorageVolume still shown as a member of the StorageRedundancySet and has an “ERROR”
status value. For Smart Array, it will remain in this state until the data drive is replaced. The CIM_Spared
association is still maintained during this time.