HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

Version 2.0.0 71
HPSA_ArraySystem
HPSA_DiskDrive
OperationalStatus:
[0] 3 (degraded)
[1] 32771 (Path In Error)
HPSA_StorageExtent
MediaPresent
HPSA_DiskDriveStorageExtent
DiskDrive Lite
HPSA_ISASSCSIProtocolEndpoint
HPSA_ISASPort
CIM_SystemDevice
HPSA_ArraySystemISASPort
Initiator Port /
SAS Initiator
CIM_HostedAccessPoint
HPSA_ArraySystemISASSCSIPE
HPSA_TSASSCSIProtocolEndpoint
HPSA_TSASPort
CIM_SystemDevice
HPSA_ArraySystemTSASPort
CIM_HostedAccessPoint
HPSA_ArraySystemTSASSCSIPE
Target Port /
SAS Target Port
CIM_SAPAvailableForElement
HPSA_DiskDriveTSASSCSIPE
HPSA_ISASPort
HPSA_TSASSCSIProtocolEndpoint
HPSA_ISASSCSIProtocolEndpoint
HPSA_TSASPort
HPSA_SCSIInitiatorTargetLogicalUnitPath
Consolidated
Status
HPSA_StorageSpecificCollection
MemberOfCollection
HPSA_StorageSpecificCollection
HP_ComputerSystem
System
CIM_ComponentCS
HPSA_ComputerSystemArraySystem
HPSA_PortController
SystemDevice
(not currently
populated by
WMI)
CIM_DeviceSAPImplementation
HPSA_TSASPortTSASSCSIPE
CIM_DeviceSAPImplementation
HPSA_ISASPortISASSCSIPE
CIM_SystemDevice
HPSA_ArraySystemStorageVolume
CIM_BasedOn
HPSA_StorageExtentStorageVolume
HPSA_SCSIInitiatorTargetLogicalUnitPath
State: 2 (Active)
HPSA_SCSIInitiatorTargetLogicalUnitPath
State: 5 (Path Error)
LogicalIdentity
HPSA_ArraySystemPortController
HPSA_StorageVolume
OperationalStatus:
[0] 3 (degraded)
[1] 32781 (Path In Error)
PhysicalDrvMultipathAccess:
4 (configured non-redundant)
Figure 37 - HP Smart Array profile: Multi-path Logical Volume changes
As shown, one path is active and another path is in error (5 path error). This status is reflected into the
HPSA_StorageVolume.OperationalStatus. The OperationalStatus primary status is 2 (degraded) and the
secondary status is 32781 (Path In Error). The status is also reflected into HPSA_DiskDrive.OpStat[0]:3
(degraded) and HPSA_DiskDrive.OpStat[1]: 32771 (Path In Error). PhysicalDrvMultipathAccess is set to
4 ‘Configured non-redundant’..
9.13 Determine Smart Drive Carrier Firmware Version
If the array controller is capable of reporting the Smart Drive carrier application firmware version, for a
given instance of HPSA_DiskDrive, select an associated instance of CIM_SoftwareIdentity through
CIM_ElementSoftwareIdentity. Retrieve the version from the CIM_SoftwareIdentity.VersionString
property.
If the array controller is capable of reporting the Smart Drive carrier bootloader firmware version, for a
given instance of HPSA_DiskDrive, select an associated instance of CIM_SoftwareIdentity through
CIM_ElementSoftwareIdentity. Retrieve the version from the CIM_SoftwareIdentity.VersionString property