HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

32 Version 2.1.0
9.5.2 Drive Failed data rebuilding
HPSAS_StorageExtent:001
OPStatus = “OK”
HPSAS_StorageExtent:003
OPStatus = “ERROR”
HPSAS_StoragePool:1
Concrete Pool
ConcreteComponent
ConcreteComponent
HPSAS_StorageRedundancySet:A
MemberOfCollection
MemberOfCollection
HPSAS_StorageExtent:004
Spare
OPStatus = “OK”
ExtentStatus = “Rebuild”
IsSpare
HPSAS_StorageVolume:100
OpStatus = “Degraded”
PercentComplete = “33”
AllocatedFromStoragePool
Spared
Figure 15 - HP SAS HBA profile: Disk sparing Drive failed - rebuilding
Figure shows the instance diagram after one of the data drives has failed. OperationalStatus will show
“ERROR” for the failed drive. The OperationalStatus for the StorageVolume will show “Degraded,
Recovering”. The OperationalStatus for the Spare drive will show “OK” and the ExtentStatus will show
“Rebuild”. The data is being rebuilt to the spare drive. The progress for the rebuild will be shown in
HPSAS_StorageVolume.PercentComplete.
The CIM_Spared association is used to associate the spare to the failed drive that it has replaced.