HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

34 Version 2.1.0
9.5.4 Drive replaced
HPSAS_StorageExtent:001
OPStatus = “OK”
HPSAS_StorageExtent:003
Spare
OPStatus = “OK”
HPSAS_StoragePool:1
Concrete Pool
ConcreteComponent
ConcreteComponent
HPSAS_StorageRedundancySet:A
MemberOfCollection
MemberOfCollection
HPSAS_StorageExtent:004
OPStatus = “OK”
IsSpare
HPSAS_StorageVolume:100
OpStatus = “OK”
AllocatedFromStoragePool
Figure 17 - HP SAS HBA profile: Drive Replaced
Figure shows the instance diagram for the case where the failed drive has been replaced with a
functional drive. The replaced drive will now act as a spare for the collection.
9.6 Host based HBA controller model
HPSAS_ArraySystem:01
OpStatus = “Degraded”
HPSAS_ArrayController:123
OpStatus = “OK”
ComponentCS
HPSAS_StorageVolume:002
OpStatus = “Degraded”
SystemDevice
Figure 18 - HP SAS HBA profile: Host HBA Controller
Figure shows the instance diagram for a SAS HBA controller. The HPSAS_ArraySystem represents the
overall array and the OperationalStatus value will contain the consolidated status for the array. The
controller instance (HPSAS_ArrayController) is associated via CIM_ComponentCS. In the above example