HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

Version 2.1.0 35
we see that the “degraded” status of a logical drive has been consolidated into
HPSAS_ArraySystem.OperationalStatus[0].
9.7 Consolidated status example
HPSAS_ArraySystem:11
OperationalStatus = OK
HPSAS_ArraySystem
OperationalStatus =
Degraded
HPSAS_StorageSpecificCollection:01
GroupOperationalStatus = Degraded
MemberOfCollection MemberOfCollection
HP_ComputerSystem
OperationalStatus = Degraded
HP_GroupHostedCollection
HPSAS_StorageVolume:001
OperationalStatus = OK
HPSAS_StorageVolume:002
OperationalStatus =
Degraded
SystemDevice
SystemDevice
HPSAS_StorageExtent:001
OperationalStatus = OK
HPSAS_StorageExtent:002
OperationalStatus = OK
BasedOn
HPSAS_StorageExtent:001
OperationalStatus = OK
HPSAS_StorageExtent:002
OperationalStatus = ERROR
BasedOn
Figure 19 - HP SAS HBA profile: Consolidated Status
Figure shows a typical instance diagram where a single drive failure in a Raid configuration will cause
elements to have “Degraded” OperationalStatus. This will be propagated up to
HPSAS_ArraySystem.OperationalStatus and so to the GroupOperationalStatus in the
HPSAS_StorageSpecificCollection to participate in the overall system OperationalStatus for the Host per
the HP Consolidated Status profile.
Note: some instances have not been included in the diagram for the sake of clarity.