HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

Version 1.2.0 17
system1:
HP_ComputerSystem
HP_ComputerSystemPackage
chassis1 :
HP_ComputerSystemChassis
fan3:HP_Fan
CIM_SystemDevice
chassis2:CIM_Chassis
CIM_Container
loc1:HP_Location
ElementLocationTagDesc: Chassis
ElementLocationTag: “2”
LocationInformation[0] – (not used)
LocationInfoDesc[0] – (not used)
chslt1:HP_Slot
loc3:HP_Location
ElementLocationTagDesc: Slot
ElementLocationTag: “1”
LocationInformation[0]: (not used)
LocationInfoDesc[0]: (not used)
chslt2:HP_Slot
loc2:HP_Location
ElementLocationTagDesc: Slot
ElementLocationTag: “2”
LocationInformation[0]: (not used)
LocationInfoDesc[0]: (not used)
chassis3:CIM_Chassis
loc1:HP_Location
ElementLocationTagDesc: Chassis
ElementLocationTag: “3”
LocationInformation[0]: (not used)
LocationInfoDesc[0]: (not used)
fanslot1:HP_Slot
CIM_ElementInConnector
fm1:HP_FanModule
loc1:HP_Location
ElementLocationTagDesc: Slot
ElementLocationTag: “1”
LocationInformation[0]: (not used)
LocationInfoDesc[0]: (not used)
CIM_Container
CIM_Realizes
CIM_Container
CIM_ElementInConnector
HP_ElementLocation
HP_ElementLocation
HP_ElementLocation
HP_ElementLocation
HP_ElementLocation
loc1:HP_Location
ElementLocationTagDesc:Fan
ElementLocationTag:”3"
LocationInformation[0] – (not used)
LocationInfoDesc[0] – (not used)
HP_ElementLocation
Figure 2 – Location Full Containment Implemented
Figure 3 shows the same system but with an implementation that does not build out the physical side of
containment hierarchy. In this case, the provider has associated the instance of HP_Fan with an
HP_Location instance that fully describes the containment of the fan using the LocationInformation and
LocationInformationDesc property arrays. From this info, the client can determine and provide the same
location string as defined for the previous instance:
Fan 3 is plugged into Slot 1 which is contained in Chassis 3 which is plugged into Slot 2 which is
contained in Chassis 2 which is contained in the Main System chassis.
This example is for illustrative purposes to show this mechanism could be used to describe complex
containment. It is recommended that systems with complex containment relationships such as those
shown in Figure 2 build out the physical side of the model.