7.3 HP_ComputerSystem (vPartition/nPartition/Virtual System) (Optional)
This section shall apply when modeling partitionable or multi-bladed computer systems.
The partition running on the bladed computer system shall follow the HP_Base Server Profile. No
additional properties are required. The property “Dedicated” will use a vendor specific value (32568 to
32570) to indicate a vPartition, nPartition, or Virtual System. This represents the top-level computer
system instance. To determine the blades that are used to form this computer system, the
CIM_HostedDependency association must be traversed to get the CIM_ComputerSystem instances
representing each of the blades.
Use of the HP_ComputerSystem instance to represent the partition instance is optional if the system is
not partitionable (or not partitioned) or uses a single bladed computer system. In such cases, a single
HP_ComputerSystem (Blade/Server Node) instance shall represent the blade and also be the top level
computer system instance.
7.4 HP_BladeEnclosureCS (Enclosure Manager/Multi-Node Server Chassis
Computer System Instance)
This section details the requirements related to the arrangement of instances and properties of instances
for implementations of this profile.
7.4.1 HP_BladeEnclosureCS.Dedicated
This property shall be supported by providing setting the value to 0 (Other).
7.4.2 HP_BladeEnclosureCS.OtherDedicatedDescriptions
This property shall be supported by providing setting the value to either “Modular” for blade systems or
“Multi-node” for multi-node server systems.
7.4.3 HP_BladeEnclosureCS.Caption
This property shall be supported by providing a short string describing the modular system enclosure or
multi-node system chassis.
7.4.4 HP_BladeEnclosureCS.Description
This property shall be supported by providing a string describing the modular system enclosure or multi-
node system chassis.
7.4.5 HP_BladeEnclosureCS.ElementName
This property shall be supported by providing a human readable string (suitable for a UI) describing the
modular system enclosure or multi-node system chassis. This should be the enclosure DNS name if
available.
7.4.6 HP_BladeEnclosureCS.SerialNumber
This property shall be supported by providing a string indicating the modular system enclosure or multi-
node system chassis serial number.
7.4.7 HP_BladeEnclosureCS.ProductID
This property shall be conditionally supported by providing a string indicating the modular system
enclosure or multi-node system chassis product id provided this information is available to the blade
system or server node.