HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

Version 1.3.0 11
7.1.5.3 HP_Fan.CurrentSpeedState
If the current fan speed state can be represented, HP_Fan.CurrentSpeedState property shall be
implemented. This property describes the current fan speed state using an appropriate enumeration
value
If CurrentSpeedState cannot be represented, the property shall return a NULL value.
7.2 HP_CoolingRedundancySet
Fan redundancy modeling is optional. Even when a managed system supports and implements the
redundancy, the redundant fans may co-exist with non-redundant fans. The conditions and requirement
placed in this section only refer to the HP_Fan instances representing redundant fans.
Fan redundancy is modeled using HP_CoolingRedundancySet which is associated to the HP_Fan
instances through HP_MemberOfCoolingRedundancy associations. Instances of
HP_CoolingRedundancySet are associated to its containing instance of CIM_ComputerSystem through
the HP_HostedCoolingRedundancySet association.
When fan redundancy is implemented, there shall be at least one instance of
HP_CoolingRedundancySet. The HP_MemberOfCoolingRedundancy association shall be used to
associate the HP_CoolingRedundancySet instance with the HP_Fan instance.
Multiple instances of HP_CoolingRedundancySet may exist. Furthermore, fan redundancy sets may
share fans; instances of HP_Fan may be members of more than one HP_CoolingRedundancySet
instance using HP_MemberOfCoolingRedundancy associations.
7.3 HP_CoolingCollection
Fan collection modeling is optional. There may be one or more instance of HP_CoolingCollection
instantiated. Instances of HP_Fan are associated to HP_CoolingCollection through the
HP_MemberOfCoolingCollection association. Instances of HP_CoolingCollection are associated to its
containing instance of CIM_ComputerSystem through the HP_HostedCoolingCollection association.
7.3.1 HP_CoolingCollection.Description
HP_CoolingCollection.Description property shall be implemented. This property shall contain the detailed
description for the collection, that includes the corresponding string value of GroupOperationalStatus[0] or
GroupStatusDescriptions[0].
7.3.2 HP_CoolingCollection.GroupOperationalStatus
HP_CoolingCollection.GroupOperationalStatus shall comprehend the status of all associated instances of
non-redundant fans and associated instances of HP_CoolingRedundancySet, if redundancy is modeled.
Non-redundant Fans
OperationalStatus[0]
Cooling RedundancySet
RedundancyStatus
GroupOperationalStatus[0]
All OK FullyRedundant
Booted with uninstalled fans:
RedundancyDegraded or
RedundancyLost and all Fan
OK