HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

12 Version 1.3.0
7.3 HP_PowerCollection
Power Supply collection modeling is optional. There may be one or more instance of
HP_PowerCollection instantiated. Instances of HP_PowerSupply are associated to HP_PowerCollection
through the HP_MemberOfPowerCollection association. Instances of HP_PowerCollection are associated
to its containing instance of CIM_ComputerSystem through the HP_HostedPowerCollection association.
HP_PowerCollection.GroupOperationalStatus shall comprehend the status of all associated instances of
non-redundant power supplies and associated instances of HP_PowerRedundancySet, if redundancy is
modeled.
7.4 HP_SystemPowerSupply
There shall be one instance of HP_SystemPower Supply instantiated for each instance of
HP_PowerSupply. This class associates an instance of HP_PowerSupply with its containing instance of
CIM_ComputerSystem.
7.5 HP_MemberOfPowerRedundancy
When power supply redundancy is implemented, there shall be at least one instance of
HP_MemberOfPowerRedundancy instantiated for each instance of HP_PowerSupply that is capable of
redundancy. This class associates an instance of redundancy-capable HP_PowerSupply to the
respective instance of HP_PowerRedundancySet.
7.6 HP_HostedPowerRedundancySet
When power supply redundancy is implemented, there shall be one instance of
HP_HostedPowerRedundancySet instantiated for each instance of HP_PowerRedundancySet. This
class associates an instance of HP_PowerRedundancySet with its containing instance of
CIM_ComputerSystem.
7.7 HP_MemberOfPowerCollection
When power supply collection is implemented, there shall be one instance of
HP_MemberOfPowerCollection instantiated for each instance of HP_PowerSupply. This class associates
an instance of HP_PowerSupply to the respective instance of HP_PowerCollection.
If the HP_MemberOfPowerRedundancy inherits from CIM_MemberOfCollection or
CIM_MemberOfPolicyCollection and the “Included” property has a value of TRUE; the power supply
status SHALL be used in state propagation rollup.
If the HP_MemberOfPowerRedundancy inherits from CIM_MemberOfPolicyCollection and the “Included”
property has a value of FALSE; the power supply status SHALL NOT be used in state propagation rollup.
The power supply status shall be ignored and considered as “OK” for the purposes of state propagation
rollup.
7.8 HP_HostedPowerCollection
When power supply collection is implemented, there shall be one instance of HP_HostedPowerCollection
instantiated for each instance of HP_PowerCollection. This class associates an instance of
HP_PowerCollection with its containing instance of CIM_ComputerSystem.
7.9 HP_SuppliesPower
Associated Power modeling is optional. If associated Power modeling is implemented, the power supply
represented by the referenced instance of HP_PowerSupply shall provide power for managed system
element represented by the referenced instance of CIM_ManagedSystemElement.