HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

14 Version 1.3.0
system1:CIM_ComputerSystem
ps2:HP_PowerSupply
OperationalStatus:
(OK)
ps1:HP_PowerSupply
OperationalStatus:
(OK)
HP_SystemPowerSupply
profile1:CIM_RegisteredProfile
RegisteredName: Base System Profile
profile1:CIM_RegisteredProfile
RegisteredName: Power Supply Profile
profile1:HP_RegisteredProfile
RegisteredName: HP Power Supply
Profile
CIM_ElementConformsToProfile
CIM_ReferencedProfile
HP_ExtendsProfile
powercollection1:HP_Power
Collection
GroupOperationalStatus:
(OK)
HP_HostedPowerCollection
HP_MemberOfPowerCollectio
n
pm2:HP_PowerMeter
pm1:HP_PowerMeter
HP_AssociatedPowerMeter
HP_AssociatedPowerMeter
Figure 3 – HP Power Supply Profile: Object Diagram
Figure 4 represents another possible instantiation of the HP Power Supply Profile, with modeled
redundancy. In this case, system1 has four power supplies: ps1, ps2, ps3 and ps4. All of the power
supplies belong to powercollection1. Power supplies ps1 and ps2 belong to powerredundancyset1.
Power supplies ps3 and ps4 belong to powerredundancyset2.
The overall group operational status of the power supplies is Error.
For simplicity most of the properties have been removed from the classes.