HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

Version 1.3.0 15
system1:HP_ComputerSystem
ps2:HP_PowerSupply
OperationalStatus:
(Failed)
ps1:HP_PowerSupply
OperationalStatus:
(Failed)
HP_SystemPowerSupply
profile1:CIM_RegisteredProfile
RegisteredName: Base System Profile
profile1:CIM_RegisteredProfile
RegisteredName: Power Supply
Profile
profile1:HP_RegisteredProfile
RegisteredName: HP Power Supply
Profile
CIM_ElementConformsToProfile
CIM_ReferencedProfile
HP_ExtendsProfile
Powercollection1:HP_Power
Collection
GroupOperationalStatus:
(Error)
ps3:HP_PowerSupply
OperationalStatus:
(OK)
ps4:HP_PowerSupply
OperationalStatus:
(OK)
powerredundancyset1:HP
_PowerRedundancySet
RedundancyStatus:
(Overall Failure)
powerredundancyset2:HP
_PowerRedundancySet
RedundancyStatus:
(Fully Redundant)
HP_MemberOfPowerRedundancy HP_MemberOfPowerRedundancy
HP_MemberOfPowerCollection
HP_HostedPowerRedundancySet
HP_HostedPowerCollection
Figure 4 – HP Power Supply Profile: Power Supply Redundancy Object Diagram
Figure 5 represents another possible instantiation of the HP Power Supply Profile, with modeled
redundancy and support for state propagation filtering. In this case, system1 has four power supplies:
ps1, ps2, ps3 and ps4. All of the power supplies belong to powercollection1. Power supplies ps1 and ps2
belong to powerredundancyset1. Power supplies ps3 and ps4 belong to powerredundancyset2.
The overall group operational status of the power supplies is Error.
For simplicity most of the properties have been removed from the classes.
Figure 5 represents a possible instantiation of the HP Power Supply Profile. In this case, system1 has a
processor and power supply, cpu1 and ps1 respectively. Ps1 is associated with cpu1 via
HP_SuppliesPower ps1 provides power for cpu1.
For simplicity most of the properties have been removed from the classes.