HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.0 U1 June 2012 Profiles

18 Version 1.3.0
Retrieve the Power Supply Group Operational Status
For the given instance of HP_PowerSupply, select the associated instance of HP_PowerCollection
through HP_MemberOfPowerCollection association. Retrieve the value of
HP_PowerCollection.GroupOperationalStatus property.
9.2 Retrieve the Power Supply Redundancy Status
For the given instance of HP_PowerSupply, select the associated instance of HP_PowerRedundancySet
through HP_MemberOfPowerRedundancy association. Retrieve the value of
HP_PowerRedundancySet.RedundancyStatus property.
9.3 Determine the Type of Power Collection
For the given instance of HP_PowerCollection, select an associated instance of HP_PowerSupply
through HP_MemberOfPowerCollection association. The type of Power Collection is described by the
associated HP_PowerSupply.PowerSupplyType property enumeration.
10 CIM Elements
The implementation requirements for the classes and properties described in this section are defined in
the “Implementation Requirements” section (Section 7).
Table 2 – CIM Elements HP Power Supply Profile
Element Name
Requirement
Description
Classes
HP_PowerSupply Mandatory See Sections 7.1 and 10.1
HP_RegisteredProfile Mandatory See Section 10.2
HP_PowerCollection Optional See Sections 7.3 and 10.3
HP_PowerRedundancySet Optional See Sections 7.2 and 10.4
HP_MemberOfPowerRedundancy Conditional See Sections 7.5 and 10.5
HP_MemberOfPowerCollection Conditional See Sections 7.7 and 10.8
HP_HostedPowerRedundancySet Conditional See Sections 7.6 and 10.6
HP_HostedPowerCollection Conditional See Sections 7.8 and 10.9
HP_SystemPowerSupply Mandatory See Sections 7.4 and 10.11
HP_SuppliesPower Optional See Sections 7.9 and 10.12
Indications
None defined in this profile
10.1 HP_PowerSupply
HP_PowerSupply is used to represent a power supply in a managed system.