HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

1-4-4 Fibre Channel Port status changed to Bypassed
HP_DeviceIndication: Fibre Channel Port status changed to Bypassed
Property name Property implementation
CIM_Indication
IndicationIdentifier
Unique identifying string generated at the time of
indication
PerceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description
This fibre channel HBA port has returned to a status of
Bypassed
AlertingManagedElement WBEM Path of SMX_FCHBAFCPort instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 4
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP FCHBA
RecommendedActions Re-enable the fibre channel port.
SystemName Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating
the indication
HP_AlertIndication
HP Insight Manager WBEM Fibre Channel Host Bus Adapter Provider 42