HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

Property Name
Property Implementation
OperationalStatus
Enumerators indicating the Management Processor operational status
(refer to OperationalStatus mapping table in HP Management
Processor Lite Profile for specific descriptions of when each value is
populated).
OperationalStatus[0] contains MP operational status:
0 (Unknown), when NICCondition=0
2 (OK), normal operation
3 (Degraded), when NICCondition=5
6 (Error), when NICCondition=6 or MP software interface fails
OperationalStatus[1]
contains NIC status (when MP is enabled):
0 (Unknown), when NICCondition=0 or MP software interface fails
2 (OK), normal operation
3 (Degraded), when NICCondition=5
6 (Error), when NICCondition=6
10 (Stopped), when NICCondition=3
15 (Dormant), when NICCondition=4
Note:
When a Management Processor is disabled (refer to property
EnabledState) OperationalStatus[0] will always report a status of
2
(OK) so as not to contribute negatively to overall system status. An MP is
disabled only if the user has manually disabled it via the MP’s RBSU
settings; this is seen as a normal condition. In this scenario
OperationalStaus[1] is not populated.
HP Insight Management WBEM Management Processor Lite Provider 5