HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

Property Name
Property Implementation
Description
Description of this power supply module, including ElementName, Type and
Status.
For example:
ElementName
provides power for PowerSupplyType.
StatusDescription
Where: ElementName represents the value of ElementName,
PowerSupplyType represents the corresponding string value of the
PowerSupplyType enumeration and StatusDescription represents the
value of
StatusDescriptions[0].
ElementName
Short description of this power supply for the name displayed by the MP or iLO
and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) if power supply is operating properly;
3 (Degraded) if power supply is degraded;
6 (Error) if power supply has failed
StatusDescriptions[0]
Description of the status of the power supply corresponding to the
OperationalStatus.
For example:
Power Supply is operating properlyif OperationalStatus[0] is
2 (OK);
Power Supply is degradedif OperationalStatus[0] is 3
(Degraded)
Power Supply has failedif OperationalStatus is 6 (Error)
HealthState
5 (OK) if power supply is operating properly;
10 (Degraded) if power supply is degraded
HP Insight Management Power Supply Provider Overview 13