HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

Property Name
Property Implementation
StatusDescriptions[0]
Description of the status of the power utilization sensor corresponding to
the OperationalStatus.
For example:
Power Supply is operating properly – if OperationalStatus[0] is 2
(OK);
HealthState
5 (OK) – if power utilization sensor is operating properly;
Name
Short description of this power utilization sensor using the name of the
power supply displayed by the MP or iLO and location.
For example:
Power utilization sensor for Power Supply 1 at
PowerSupplySlot=1.
CIM_LogicalDevice:
CreationClassName
SMX_PowerMeter
DeviceID
Unique identifier for this power utilizaton sensor.
SystemCreationClassName
SMX_ComputerSystem.CreationClassName
SystemName
SMX_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
CIM_Sensor
SensorType
13 (Power Consumption)
CurrentState
β€œNormal”
HP Insight Management Power Supply Provider Overview 19